Ovation™ Model 128 |
Complete
with attractive styling and a price that will surprise you,
the Ovation™ 128 series is turning heads all across the country.
Your customers still receive that "big bed" feeling yet it
conveniently
fits in a 7’ x 8’ room. The 128 comes standard with 28 staggered
Rave™
lamps and an optional 400 watt face tanner.
|
Specifications for Ovation™ 128:
|
28 Lamp Heartland Rave system – 20 minute session
8 Heartland Rave 5071 100 watt lamps in canopy
6 Heartland Rave 5059 80 watt lamps in canopy
14 Heartland Rave 5071 100 watt lamps in bench
T-Max timer on board (T-Max wireless compatible)
Works in a drawer component tray underneath bench
*30 AMP single phase, 220 – 240 volt with ground required
(for optimum performance, running voltage should be 230 – 240)
*21 AMPS initial start up, 17 AMPS running at 220 VAC
.75 KVA Buck/Boost transformer may be required if outside 220 – 240 VAC
7’ X 8’ minimum room size required
¾ Ton (9,000 BTU) minimum A/C dedicated into room
Shipping weight: 702lbs.
Dimensions: 871/2”L X 36”W
5 Year Limited Warranty
|
|
|
|
Type B seal tight connector supplied. Located lower back in center of bed.
Type B flexible conduit required. *Actual amp reading will vary depending on
voltage-electrician must calculate load/line side amps when using a Buck/Boost
transformer to insure proper wire gauge and breaker size.
Minimum 8 gauge wire size is recommended for this 30 amp circuit to allow
less than 2% voltage drop up to 100 feet. Licensed electrician must refer to
National Electric Codes when determining proper wire gauge and breaker size
for each application. All specifications are subject to change.
|
Specifications for Ovation™ 128/1:
|
28 Lamp Heartland Rave system – 20 minute session
8 Heartland Rave 5071 100 watt lamps in canopy
6 Heartland Rave 5059 80 watt lamps in canopy
14 Heartland Rave 5071 100 watt lamps in bench
(1) 400 watt facial lamp
T-Max timer on board (T-Max wireless compatible)
Works in a drawer component tray underneath bench
*30 AMP single phase, 220 – 240 volt with ground required
(for optimum performance, running voltage should be 230 – 240)
*19 AMPS initial start up, 19 AMPS running @ 220 VAC
.75 Buck/Boost transformer may be required if outside 220 – 240 VAC
7’ X 8’ minimum room size required
¾ Ton (9,000 BTU) minimum A/C dedicated into room
Shipping weight: 710lbs.
Dimensions: 871/2”L X 36”W
5 Year Limited Warranty
|
|
|
|
Type B seal tight connector supplied. Located lower back in center of bed.
Type B flexible conduit required. *Actual amp reading will vary depending on
voltage-electrician must calculate load/line side amps when using a Buck/Boost
transformer to insure proper wire gauge and breaker size.
Minimum 8 gauge wire size is recommended for this 30 amp circuit to allow
less than 2% voltage drop up to 100 feet. Licensed electrician must refer to
National Electric Codes when determining proper wire gauge and breaker size
for each application. All specifications are subject to change.
|
|
|
|